180 research outputs found

    Commissioning and operation of the Cherenkov detector for proton Flux Measurement of the UA9 Experiment

    Full text link
    The UA9 Experiment at CERN-SPS investigates channeling processes in bent silicon crystals with the aim to manipulate hadron beams. Monitoring and characterization of channeled beams in the high energy accelerators environment ideally requires in-vacuum and radiation hard detectors. For this purpose the Cherenkov detector for proton Flux Measurement (CpFM) was designed and developed. It is based on thin fused silica bars in the beam pipe vacuum which intercept charged particles and generate Cherenkov light. The first version of the CpFM is installed since 2015 in the crystal-assisted collimation setup of the UA9 experiment. In this paper the procedures to make the detector operational and fully integrated in the UA9 setup are described. The most important standard operations of the detector are presented. They have been used to commission and characterize the detector, providing moreover the measurement of the integrated channeled beam profile and several functionality tests as the determination of the crystal bending angle. The calibration has been performed with Lead (Pb) and Xenon (Xe) beams and the results are applied to the flux measurement discussed here in detail.Comment: 25 pages, 14 figure

    Experimental results of crystal-assisted slow extraction at the SPS

    Full text link
    The possibility of extracting highly energetic particles from the Super Proton Synchrotron (SPS) by means of silicon bent crystals has been explored since the 1990's. The channelling effect of a bent crystal can be used to strongly deflect primary protons and eject them from the synchrotron. Many studies and experiments have been carried out to investigate crystal channelling effects. The extraction of 120 and 270 GeV proton beams has already been demonstrated in the SPS with dedicated experiments located in the ring. Presently in the SPS, the UA9 experiment is performing studies to evaluate the possibility to use bent silicon crystals to steer particle beams in high energy accelerators. Recent studies on the feasibility of extraction from the SPS have been made using the UA9 infrastructure with a longer-term view of using crystals to help mitigate slow extraction induced activation of the SPS. In this paper, the possibility to eject particles into the extraction channel in LSS2 using the bent crystals already installed in the SPS is presented. Details of the concept, simulations and measurements carried out with beam are presented, before the outlook for the future is discussed.Comment: 4 pages, 7 figures, submitted to to International Particle Accelerator Conference (IPAC) 2017 in Copenhagen, Denmar

    The UA9 experimental layout

    Full text link
    The UA9 experimental equipment was installed in the CERN-SPS in March '09 with the aim of investigating crystal assisted collimation in coasting mode. Its basic layout comprises silicon bent crystals acting as primary collimators mounted inside two vacuum vessels. A movable 60 cm long block of tungsten located downstream at about 90 degrees phase advance intercepts the deflected beam. Scintillators, Gas Electron Multiplier chambers and other beam loss monitors measure nuclear loss rates induced by the interaction of the beam halo in the crystal. Roman pots are installed in the path of the deflected particles and are equipped with a Medipix detector to reconstruct the transverse distribution of the impinging beam. Finally UA9 takes advantage of an LHC-collimator prototype installed close to the Roman pot to help in setting the beam conditions and to analyze the efficiency to deflect the beam. This paper describes in details the hardware installed to study the crystal collimation during 2010.Comment: 15pages, 11 figure, submitted to JINS

    Relationship between fatty acids composition/antioxidant potential of breast milk and maternal diet: Comparison with infant formulas

    Get PDF
    The fatty acid composition of human breast milk is relevant for the energy, immunity and eicosanoid production in infants. Additionally, the antioxidant properties of foods are essential for human health. Therefore, in the present study we aimed to investigate the relationship between maternal diet and fatty acids composition as well as the antioxidant potential of breast milk from donors to human milk bank of Perugia\u2019s hospital, Italy. Results were compared with infant formulas. We observed increased levels of total fatty acids and, in particular, saturated and monounsaturated fatty acids in milk from mothers fed on a vegetable and fruit-rich diet compared with a Mediterranean diet. In the same milk, a reduced antioxidant potential was found. All infant formulas resulted in richer total fatty acid content than human breast milk. Only some formulas were qualitatively similar to breast milk. Of note, the antioxidant potential of the formulas was higher or lower than the human milk with the exception of one sample. The antioxidant potential of four formulas was very high. Dietary supplementation with antioxidants has been shown to have a teratogenic effect and to increase the formation of metastases in adult. There are no data on the effects of excess antioxidants in the infants, but the possibility that they can be harmful cannot be excluded

    Survival Data and Predictors of Functional Outcome an Average of 15 Years after the Fontan Procedure: The Pediatric Heart Network Fontan Cohort

    Full text link
    ObjectiveMulticenter longitudinal outcome data for Fontan patients surviving into adulthood are lacking. The aim of this study was to better understand contemporary outcomes in Fontan survivors by collecting follow‐up data in a previously well‐characterized cohort.DesignBaseline data from the Fontan Cross‐Sectional Study (Fontan 1) were previously obtained in 546 Fontan survivors aged 11.9 ± 3.4 years. We assessed current transplant‐free survival status in all subjects 6.8 ± 0.4 years after the Fontan 1 study. Anatomic, clinical, and surgical data were collected along with socioeconomic status and access to health care.ResultsThirty subjects (5%) died or underwent transplantation since Fontan 1. Subjects with both an elevated (>21 pg/mL) brain natriuretic peptide and a low Child Health Questionnaire physical summary score (<44) measured at Fontan 1 were significantly more likely to die or undergo transplant than the remainder, with a hazard ratio of 6.2 (2.9–13.5). Among 516 Fontan survivors, 427 (83%) enrolled in this follow‐up study (Fontan 2) at 18.4 ± 3.4 years of age. Although mean scores on functional health status questionnaires were lower than the general population, individual scores were within the normal range in 78% and 88% of subjects for the Child Health Questionnaire physical and psychosocial summary score, and 97% and 91% for the SF‐36 physical and mental aggregate score, respectively. Since Fontan surgery, 119 (28%) had additional cardiac surgery; 55% of these (n = 66) in the interim between Fontan 1 and Fontan 2. A catheter intervention occurred in 242 (57%); 32% of these (n = 78) after Fontan 1. Arrhythmia requiring treatment developed in 118 (28%) after Fontan surgery; 58% of these (n = 68) since Fontan 1.ConclusionsWe found 95% interim transplant‐free survival for Fontan survivors over an average of 7 years of follow‐up. Continued longitudinal investigation into adulthood is necessary to better understand the determinants of long‐term outcomes and to improve functional health status.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/110738/1/chd12193.pd

    High-efficiency deflection of high energy protons due to channeling along the (110) axis of a bent silicon crystal

    Get PDF
    A deflection efficiency of about 61% was observed for 400 GeV/c protons due to channeling, most strongly along the 〈110〉 axis of a bent silicon crystal. It is comparable with the deflection efficiency in planar channeling and considerably larger than in the case of the 〈111〉 axis. The measured probability of inelastic nuclear interactions of protons in channeling along the 〈110〉 axis is only about 10% of its amorphous level whereas in channeling along the (110) planes it is about 25%. High efficiency deflection and small beam losses make this axial orientation of a silicon crystal a useful tool for the beam steering of high energy charged particles

    Handling 1 MW losses with the LHC collimation system

    Get PDF
    The LHC superconducting magnets in the dispersion suppressor of IR7 are the most exposed to beam losses leaking from the betatron collimation system and represent the main limitation for the halo cleaning. In 2013, quench tests were performed at 4 TeV to improve the quench limit estimates, which determine the maximum allowed beam loss rate for a given collimation cleaning. The main goal of the collimation quench test was to try to quench the magnets by increasing losses at the collimators. Losses of up to 1 MW over a few seconds were generated by blowing up the beam, achieving total losses of about 5.8 MJ. These controlled losses exceeded by a factor 2 the collimation design value, and the magnets did not quench.peer-reviewe

    FCC-ee: The Lepton Collider – Future Circular Collider Conceptual Design Report Volume 2

    Get PDF
    corecore